Master Red Lion, HMS & Industrial Protocols
Hands-on training for Red Lion and HMS communication gateways using EtherNet/IP, Modbus Serial and Modbus TCP/IP — built for technicians, engineers and industrial support teams.
Connect PLCs, HMIs, Drives and Legacy Devices
Learn how to configure industrial gateways for protocol conversion, device mapping, register addressing and real-world plant communication troubleshooting.
Red Lion Gateways
Configure protocol conversion, data tags, register mapping and HMI/PLC device communication.
HMS Anybus
Set up Anybus gateways for PLC-to-device communication across industrial networks.
EtherNet/IP
Understand scanner/adapter concepts, assemblies, data mapping and PLC integration.
Modbus Protocols
Work with Modbus RTU, Modbus ASCII and Modbus TCP/IP addressing and diagnostics.
From Protocol Basics to Live Gateway Commissioning
A structured pathway for industrial teams working with PLC communication, Modbus devices, Ethernet networks and protocol gateways.
01. Industrial Communication Fundamentals
Understand protocol layers, device roles, IP addressing, serial settings, network topology and common communication failure points.
02. EtherNet/IP Integration
Configure EtherNet/IP scanner/adapter relationships, assembly instances, input/output data size and PLC tag mapping.
03. Modbus Serial — RTU / ASCII
Set up baud rate, parity, stop bits, slave IDs, RS-232/RS-485 wiring, function codes and register addressing.
04. Modbus TCP/IP
Configure TCP devices, unit IDs, holding registers, coils, input registers, polling rates and network diagnostics.
05. Red Lion Gateway Configuration
Create device profiles, map tags, convert protocols, build data blocks and test communication between PLCs and field devices.
06. HMS Anybus Gateway Configuration
Configure Anybus modules for protocol translation, data exchange, diagnostics and integration with PLC systems.
07. Troubleshooting & Commissioning
Use diagnostic LEDs, ping tests, web interfaces, serial monitors, Modbus scanners and PLC status data to solve real faults.
Map Data. Convert Protocols. Diagnose Faults.
Participants work with real communication modules, PLC connections, serial devices and Ethernet networks to understand how industrial data moves between machines.
Built for Industrial Network Troubleshooting
Ideal For
- Electricians working with PLC panels and serial devices.
- Maintenance technicians troubleshooting network faults.
- Control engineers integrating third-party equipment.
- OEM builders using Red Lion, HMS Anybus or Modbus devices.
Why TS Automation?
- Australian automation engineers with real commissioning experience.
- Training focused on practical data mapping and fault finding.
- Examples from PLC, SCADA, VSD, metering and gateway projects.
- Individual and group training options available.
Ready to Build Communication Gateway Confidence?
Enrol individually or request a group booking for your electrical, maintenance, automation or commissioning team.
Master Red Lion, HMS & Industrial Protocols
Hands-on training for Red Lion and HMS communication gateways using EtherNet/IP, Modbus Serial and Modbus TCP/IP — built for technicians, engineers and industrial support teams.
Connect PLCs, HMIs, Drives and Legacy Devices
Learn how to configure industrial gateways for protocol conversion, device mapping, register addressing and real-world plant communication troubleshooting.
Red Lion Gateways
Configure protocol conversion, data tags, register mapping and HMI/PLC device communication.
HMS Anybus
Set up Anybus gateways for PLC-to-device communication across industrial networks.
EtherNet/IP
Understand scanner/adapter concepts, assemblies, data mapping and PLC integration.
Modbus Protocols
Work with Modbus RTU, Modbus ASCII and Modbus TCP/IP addressing and diagnostics.
From Protocol Basics to Live Gateway Commissioning
A structured pathway for industrial teams working with PLC communication, Modbus devices, Ethernet networks and protocol gateways.
01. Industrial Communication Fundamentals
Understand protocol layers, device roles, IP addressing, serial settings, network topology and common communication failure points.
02. EtherNet/IP Integration
Configure EtherNet/IP scanner/adapter relationships, assembly instances, input/output data size and PLC tag mapping.
03. Modbus Serial — RTU / ASCII
Set up baud rate, parity, stop bits, slave IDs, RS-232/RS-485 wiring, function codes and register addressing.
04. Modbus TCP/IP
Configure TCP devices, unit IDs, holding registers, coils, input registers, polling rates and network diagnostics.
05. Red Lion Gateway Configuration
Create device profiles, map tags, convert protocols, build data blocks and test communication between PLCs and field devices.
06. HMS Anybus Gateway Configuration
Configure Anybus modules for protocol translation, data exchange, diagnostics and integration with PLC systems.
07. Troubleshooting & Commissioning
Use diagnostic LEDs, ping tests, web interfaces, serial monitors, Modbus scanners and PLC status data to solve real faults.
Map Data. Convert Protocols. Diagnose Faults.
Participants work with real communication modules, PLC connections, serial devices and Ethernet networks to understand how industrial data moves between machines.
Built for Industrial Network Troubleshooting
Ideal For
- Electricians working with PLC panels and serial devices.
- Maintenance technicians troubleshooting network faults.
- Control engineers integrating third-party equipment.
- OEM builders using Red Lion, HMS Anybus or Modbus devices.
Why TS Automation?
- Australian automation engineers with real commissioning experience.
- Training focused on practical data mapping and fault finding.
- Examples from PLC, SCADA, VSD, metering and gateway projects.
- Individual and group training options available.
Ready to Build Communication Gateway Confidence?
Enrol individually or request a group booking for your electrical, maintenance, automation or commissioning team.